INSTALLATION INSTRUCTIONS AND SAFETY INFORMATIONFOR THE VIKING R-6 GATE OPERATORCLASS I Residential Vehicular Swing Gate OperatorCLASS I
VIKING TECHNICAL SUPPORT 1.800.908.08848IMPORTANT SAFETY INFORMATIONMAINTENANCERemove the Power Harness from the Control Board. (refer to page 18)•Cl
VIKING TECHNICAL SUPPORT 1.800.908.08849! CAUTION: To Reduce the Risk of Fire or Injury to Persons:IMPORTANT SAFETY INFORMATIONInstall the gate operat
VIKING TECHNICAL SUPPORT 1.800.908.088410IMPORTANT SAFETY INFORMATIONNOTE: This type on installation DOES NOT reverse the gate all the way back to its
VIKING TECHNICAL SUPPORT 1.800.908.088411NOTE: This type on installation DOES NOT reverse the gate all the way back to its limits when the edge sensor
VIKING TECHNICAL SUPPORT 1.800.908.088412Audible Alarm Reset Switch InstallationManual Reset for the Audible Alarm•UL325 standard requires an audible
VIKING TECHNICAL SUPPORT 1.800.908.088413! CAUTION: To Reduce the Risk of Fire or Injury to Persons:! WARNING: For use with gates at a maximum 700 lbs
VIKING TECHNICAL SUPPORT 1.800.908.088414GATE OPERATOR INSTALLATION Concrete Pad Option1. Follow the local building code to determine the required dep
VIKING TECHNICAL SUPPORT 1.800.908.088415Post Mounting OptionTIP: The operator can be post mounted to be elevated above snow and flood lines.1. Consul
VIKING TECHNICAL SUPPORT 1.800.908.088416Operator Positioning! IMPO RTANT: Swing Gates must not open into public access areas.The gate must be install
VIKING TECHNICAL SUPPORT 1.800.908.088417GATE OPERATOR INSTALLATIONSTEP 1Install the Clutch and cut the Arm Assembly to achieve the desired dimensions
The R-6™ swing gate operator is capable of handling gates up to 700 lbs. and 14 ft long. With its effi cient drivetrain, robust stature, bui
VIKING TECHNICAL SUPPORT 1.800.908.088418High Voltage Supply Option! Caution: Always turn off power breakers when working with high voltage. DO NOT co
VIKING TECHNICAL SUPPORT 1.800.908.088419Low Voltage Supply OptionTIP: As an alternative to high voltage, the operator can be power by 24VAC. It is re
VIKING TECHNICAL SUPPORT 1.800.908.088420LIMITS SETUPTip: Referring to Step 2b. The “Cam Holder” contains four (4) Guide Pin holes to allow for proper
VIKING TECHNICAL SUPPORT 1.800.908.088421LIMITS SETUP! IMPORTANT: This gate operator uses mechanical limit switches. Therefore, the limits cannot be s
VIKING TECHNICAL SUPPORT 1.800.908.088422Two Wire Communication! IMPORTANT: DO NOT run the Master/Slave communication cable in the same conduit or wit
VIKING TECHNICAL SUPPORT 1.800.908.088423Wireless Communication Options! Technical Tip: DO NOT set the “Timer” and/or “Overlap” features on both opera
VIKING TECHNICAL SUPPORT 1.800.908.088424Initial SettingsCONTROL BOARD SETUP“Speed”Motor SpeedIncreases or decreases the speed of gate travel.“Overlap
VIKING TECHNICAL SUPPORT 1.800.908.088425Initial SettingsNOTE: Installing a shunt or jumper on the pins will activate the feature.CONTROL BOARD SETUP!
VIKING TECHNICAL SUPPORT 1.800.908.088426Obstruction Sensor (Primary Entrapment Protection)! IMPORTANT: The appropriate “ODS” setting is dependant upo
VIKING TECHNICAL SUPPORT 1.800.908.088427CONTROL BOARD SETUPHEATERCLS ONLOCK MODONViking HeaterThe operator has an integrated heater that is thermos
R-6 Vehicular Gate Operator • Revision R6NXMN10.D • October 2014
VIKING TECHNICAL SUPPORT 1.800.908.088428(THIS PAGE LEFT BLANK INTENTIONALLY)
VIKING TECHNICAL SUPPORT 1.800.908.088429ACCESSORY CONNECTIONS! TECHNICAL TIP: For more information regarding accessory connections to the control boa
VIKING TECHNICAL SUPPORT 1.800.908.088430ACCESSORY CONNECTIONS! TECHNICAL TIP: For more information regarding accessory connections and terminal funct
VIKING TECHNICAL SUPPORT 1.800.908.088431Anti-Tailgate, Open Commands & Guard Station! TECHNICAL TIP: For more information regarding accessory con
VIKING TECHNICAL SUPPORT 1.800.908.088432Viking Loop RackTIP: This operator may be equipped with a pre-wired Loop Rack that plug-in type loop detector
VIKING TECHNICAL SUPPORT 1.800.908.088433Guidelines for Loop InstallationTable C - Recommended Number of TurnsPerimeter (ft.) Number of Turn
VIKING TECHNICAL SUPPORT 1.800.908.088434ACCESSORY CONNECTIONS( + )( + )( + )( + )Magnetic LockLock SolenoidMagnetic Lock, Lock SolenoidNOTE: Viking A
VIKING TECHNICAL SUPPORT 1.800.908.088435Barrier Arm (B-12) Synchronization OptionNOTE: The Control Board provides a convenient solution for applicati
VIKING TECHNICAL SUPPORT 1.800.908.088436LED ReferencesIn addition to the LCD Display, the control board LEDs monitor the various circuits of the cont
VIKING TECHNICAL SUPPORT 1.800.908.088437LED ReferencesUse the table below to identify the corresponding “TS Ref#” and refer to page 38-41 for further
VIKING TECHNICAL SUPPORT 1.800.908.08842PARTS DIAGRAM:Item Description Part No.1 Cover Bolt (2) VASWCB 2 Operator Cover VAR6CO203 Output Shaf
VIKING TECHNICAL SUPPORT 1.800.908.088438TROUBLESHOOTINGLCD MSG MeaningPage 41 TS Ref #s VIKING ACCESSWelcome MessageMODEL R6Indicates the Model
VIKING TECHNICAL SUPPORT 1.800.908.088439TROUBLESHOOTINGLCD Display ReferencesLCD MSG MeaningPage 41 TS Ref #sMulti Meter DisplaysMOT AMP __._ AThis
VIKING TECHNICAL SUPPORT 1.800.908.088440TROUBLESHOOTINGLCD Display References LCD MSG MeaningPage 37 TS Ref #sError MessagesERR AC LOWIndicates th
VIKING TECHNICAL SUPPORT 1.800.908.088441TROUBLESHOOTINGSolutionsBegin the troubleshooting process by referring to the error messages on the LCD Displ
VIKING TECHNICAL SUPPORT 1.800.908.088442Access Control ConnectionsAppendix (A)! TECHNICAL TIP: Each input Terminal (i.e. Radio, Exit, Re-Open, UL) ha
VIKING TECHNICAL SUPPORT 1.800.908.088443APPENDIX (A)In GeneralIn regards to the Viking control board, all external safety devices and access controls
VIKING TECHNICAL SUPPORT 1.800.908.088444Common Radio Receivers - ConnectionsAppendix (B)Common Radio Receivers - ConnectionsAppendix (B)
VIKING TECHNICAL SUPPORT 1.800.908.088445Solar ApplicationsNOTE: Viking recommends Solar Package (part # VA-SOCHP) for most general solar applications
VIKING TECHNICAL SUPPORT 1.800.908.088446VIKING EXPANSION PRODUCTSVIKING SOLAR KIT The components included in this package are intended to provide suf
OUR CONTINUOUS COMMITMENT TO EXCELLENCEViking Access Systems is continuously working hard to identify and design products that will appeal to
VIKING TECHNICAL SUPPORT 1.800.908.08843OPERATOR REFERENCES:1. COVER BOLTS2. OUTPUT SHAFT COVER (HAT)3. OUTPUT SHAFT KNOB secures Hat; remove to
VIKING ACCESS SYSTEMS631 Wald Irvine, CA 92618Phone 800.908.0884Fax 949.753.1640www.vikingaccess.comSTANDARD FEATURESAND OPERATOR SPECIFICATIONSINSTAL
VIKING TECHNICAL SUPPORT 1.800.908.08844CONTROL BOARD REFERENCES:1. POWER HARNESS CONNECTOR provides power to the control board. pg 18-192. “OPEN LE
VIKING TECHNICAL SUPPORT 1.800.908.08845TABLE OF CONTENTS:PARTS DIAGRAM/PARTS LIST 2OPERATOR REFERENCES 3CONTROL B
VIKING TECHNICAL SUPPORT 1.800.908.08846IMPORTANT SAFETY INFORMATION! WARNING! Not Following these instructions may cause severe injury or death.IMPOR
VIKING TECHNICAL SUPPORT 1.800.908.08847IMPORTANT SAFETY INFORMATION! WARNING! Not Following these instructions may cause severe injury or death.IMPOR
Kommentare zu diesen Handbüchern